525 research outputs found

    Adaptive Protection and Control in Power System for Wide-Area Blackout Prevention

    Get PDF
    This paper presents a new approach in adaptive outof-step (OOS) protection settings in power system in real-time. The proposed method uses extended equal area criterion (EEAC) to determine the critical clearing time (CCT) and critical clearing angle (CCA) of the system, which are vital information for OOS protection setting calculation. The dynamic model parameters and the coherency groups of the system for EEAC analysis are determined in real time to ensure that the newly calculated settings suit with the prevalent system operating condition. The effectiveness of the method is demonstrated in a simulated data from 16-machine 68-bus system model

    A probabilistic approach to model-based adaptive control for damping of interarea oscillations

    No full text
    Published versio

    Frequency Restoration Reserve Control Scheme with Participation of Industrial Loads

    No full text
    In order to accommodate larger amounts of renewable energy resources, whose power output is inherently unpredictable, there is an increasing need for frequency control power reserves. Loads are already used to provide replacement reserves, i.e. the slowest kind of reserves, in several power systems. This paper proposes a control scheme for frequency restoration reserves with participation of industrial loads. Frequency restoration reserves are required to change their active power within a time frame of tens of seconds to tens of minutes in response to a regulation signal. Industrial loads in many cases already have the capacity and capability to participate in this service. A mapping of their process constraints to power and energy demand is proposed in order to integrate industrial loads in existing control schemes. The proposed control scheme has been implemented in a 74-bus test system. Dynamic simulations show that industrial loads can be successfully integrated into the power system as frequency restoration reserves. © 2013 IEEE

    Monitoring and management of power transmission dynamics in an industrial smart grid

    Get PDF
    This article is a position paper whose purpose is to give the context for presentations in a special session at PowerTech 2013. The special session is being proposed by the EU FP7 Real-Smart Consortium, a Marie Curie Industry-Academic Pathways and Partnerships project. The paper gives an overview of topics on modeling, monitoring and management of power transmission dynamics with participation from large industrial loads. © 2013 IEEE

    Multi-phase state estimation featuring industrial-grade distribution network models

    Get PDF
    This paper proposes a novel implementation of a multi-phase distribution network state estimator which employs industrial-grade modeling of power components and measurements. Unlike the classical voltage-based and current-based state estimators, this paper presents the implementation details of a constrained weighted least squares state calculation method that includes standard three-phase state estimation capabilities in addition to practical modeling requirements from the industry; these requirements comprise multi-phase line configurations, unsymmetrical and incomplete transformer connections, power measurements on 4-connected loads, cumulative-type power measurements, line-to-line voltage magnitude measurements, and reversible line drop compensators. The enhanced modeling equips the estimator with capabilities that make it superior to a recently presented state-of-the-art distribution network load estimator that is currently used in real-life distribution management systems; comparative performance results demonstrate the advantage of the proposed estimator under practical measurement schemes

    The adequacy of the present practice in dynamic aggregated modelling of wind farm systems

    Get PDF
    Large offshore wind farms are usually composed of several hundred individual wind turbines, each turbine having its own complex set of dynamics. The analysis of the dynamic interaction between wind turbine generators (WTG), interconnecting ac cables, and voltage source converter (VSC) based High Voltage DC (HVDC) system is difficult because of the complexity and the scale of the entire system. The detailed modelling and modal analysis of a representative wind farm system reveal the presence of several critical resonant modes within the system. Several of these modes have frequencies close to harmonics of the power system frequency with poor damping. From a computational perspective the aggregation of the physical model is necessary in order to reduce the degree of complexity to a practical level. This paper focuses on the present practices of the aggregation of the WTGs and the collection system, and their influence on the damping and frequency characteristics of the critical oscillatory modes. The effect of aggregation on the critical modes are discussed using modal analysis and dynamic simulation. The adequacy of aggregation method is discussed

    Series voltage regulator for radial DC-microgrid

    Get PDF
    The concept of a novel series voltage regulator (SVR) for controlling the dc-bus voltage of a radial dc microgrid is presented in this paper. The proposed SVR uses a dual-active-bridge dc-dc converter followed by a full-bridge dc-dc converter. It injects dynamic voltage in series with the dc grid to compensate resistive drop over the network. As a result, the voltage level at the different points of the grid becomes independent of load variation and stays within the specified limit. Note that the required power rating of the SVR is very low (say 2.7%) compared to the load demand considering 5% voltage regulation. In this paper, the voltage regulator is connected at the midpoint of the grid, but it may be connected in some other locations to get optimal rating of the same. The proposed configuration is simulated in MATLAB/SIMULINK at a 380-V level to check the dynamic performance under various operating conditions. A scaled-down version (at 30-V level) of the proposed system is developed in the laboratory to experimentally validate the concept. The results show the effectiveness of such a voltage regulator for the radial dc microgrid, especially under critical load condition

    Bad data detection in the context of leverage point attacks in modern power networks

    No full text
    This paper demonstrates a concept to detect bad data in state estimation when the leverage measurements are tampered with gross error. The concept is based on separating leverage measurements from non-leverage measurements by a technique called diagnostic robust generalized potential (DRGP), which also takes care of the masking or swamping effect, if any. The methodology then detects the erroneous measurements from the generalized studentized residuals (GSR). The effectiveness of the method is validated with a small illustrative example, standard IEEE 14-bus and 123-bus unbalanced network models and compared with the existing methods. The method is demonstrated to be potentially very useful to detect attacks in smart power grid targeting leverage points in the system

    Voltage control performance of AWS connected for grid operation

    Get PDF
    Published versio
    corecore